Thailand Ministry of Public Health (national diabetic retinopathy screening programme)
Deep-learning eye screening at primary care clinics, built with Google Health
An AI eye-screening tool matched retina specialists in 7,651 Thai patients, but nurses in rural clinics struggled with image quality and slow connections
Problem
Diabetic retinopathy can cause blindness, and patients in Thailand often waited four to five weeks for an ophthalmologist's result. Fewer than half of diabetic patients were screened each year.
Approach
Google Health's deep-learning system graded retinal photos taken by nurses at primary care clinics in Thailand's national screening programme, with retina specialists over-reading each image as a safety check. A prospective study ran at nine sites from December 2018 to March 2020. A separate field study observed nurses at eleven clinics in Pathum Thani and Chiang Mai.
Results
Takeaway
Accuracy held up in the clinics, but the field study found that a lack of sufficiently dark rooms, blurry images and weak internet limited use. The authors said workflows must be fitted to each setting before scaling.
Categories
- Size
- Large enterprise
- Industry
- Healthcare and life sciences
- Business function
- Production and quality
- Innovation type
- Process innovation
- AI technology
- Computer vision
- Adoption
- Co-developed with a partner
- Evidence
- Independent study
Sources
Source summaries
Researchers conducted a prospective study at nine Thai primary care sites from December 2018 to March 2020. Of 7,940 patients screened, 7,651 were eligible. For vision-threatening disease the system had 91.4% sensitivity and 95.4% specificity, against 84.8% and 95.5% for retina specialists. The authors say it matched specialists and that workflows matter when scaling.
Researchers observed and interviewed nurses at eleven Thai clinics. Resource-limited clinics struggled to produce images that met the model's quality thresholds, and screening workflows and patient experience shaped how the tool performed.
TechCrunch summarised the field study. Only two of the clinics had a room dark enough for good images, uploads took 60 to 90 seconds on slow connections, and a two-hour outage halved one clinic's screening from 200 to 100 patients. The system rejected blurry or dark images, which frustrated nurses.
Full details are in the original sources.